690427:0812 Update Infras #01
This commit is contained in:
@@ -0,0 +1,858 @@
|
||||
# Switch Configuration Guide — Omada SDN V6
|
||||
|
||||
**Version:** 3.0
|
||||
**Last Updated:** 2026-04-24
|
||||
**Status:** Production
|
||||
**Author:** Infrastructure Team
|
||||
**Maintainer:** NAP-DMS DevOps
|
||||
**Scope:** LCBP3 Network Infrastructure (SG3210X-M2 + SG2428P)
|
||||
|
||||
---
|
||||
|
||||
## Table of Contents
|
||||
|
||||
1. [Overview](#overview)
|
||||
2. [VLAN Definitions](#vlan-definitions)
|
||||
3. [Port Profiles](#port-profiles)
|
||||
4. [VLAN Mapping](#vlan-mapping)
|
||||
5. [Network Diagram](#network-diagram)
|
||||
6. [Configuration Procedure](#configuration-procedure)
|
||||
7. [Change Log](#change-log)
|
||||
8. [Quick Reference](#quick-reference--edit-port-values)
|
||||
9. [Pre-Deployment Checklist](#pre-deployment-checklist)
|
||||
10. [Testing Guide](#testing-guide--vlan--lacp--stp)
|
||||
11. [Security & Optimization](#security--optimization-recommended)
|
||||
12. [Related Documents](#related-documents)
|
||||
|
||||
---
|
||||
|
||||
## Overview
|
||||
|
||||
เอกสารนี้กำหนด Port Profile templates และ VLAN mapping configuration สำหรับ LCBP3 network infrastructure โดยใช้ TP-Link Omada SDN V6 Controller (OC200)
|
||||
|
||||
**Audience:** Network Administrator, DevOps Engineer
|
||||
**Prerequisites:** Omada SDN Controller v6.x, สิทธิ์ Admin บน OC200
|
||||
**Related ADRs:** ADR-016 (Security), ADR-009 (Database Strategy — ถ้ามี Network DB)
|
||||
|
||||
### Network Equipment
|
||||
|
||||
| Device | Model | Role |
|
||||
|--------|-------|------|
|
||||
| Core Switch | SG3210X-M2 | 10G Core Switch |
|
||||
| Access Switch | SG2428P | PoE Access Switch |
|
||||
| NAS Storage | QNAP / ASUSTOR | Network Attached Storage |
|
||||
| Unmanaged Switch 1 | TL-SG1210P | IP Phone + PC |
|
||||
| Unmanaged Switch 2 | TL-SL1226P | CCTV |
|
||||
| Wireless AP | EAP610 | Wi-Fi Access Points |
|
||||
| Router | ER7206 | Edge Router |
|
||||
|
||||
### Configuration Concepts
|
||||
|
||||
**Port Profile** — Template defining port-level settings (STP Security, Loopback Control, Multicast Fast Leave, Flow Control, EEE, LLDP-MED, PoE). Port Profiles do NOT contain VLAN configuration.
|
||||
|
||||
**Edit Port** — VLAN assignment step where Native Network (Untagged), Tagged Network, and Voice Network are configured, and a Port Profile is applied.
|
||||
|
||||
---
|
||||
|
||||
## 🧠 Key Concepts (Before Using This Config)
|
||||
|
||||
- ใช้ **STP เท่านั้น (เลิก Loop Detection)** — Spanning Tree Protocol สำหรับ loop prevention
|
||||
- **Harden Access Port ด้วย BPDU Guard** — ป้องกันการเสียบ switch โดยไม่ได้รับอนุญาต
|
||||
- **กัน Rogue Switch ด้วย Root Guard** — ป้องกัน switch เถื่อนยึด root bridge
|
||||
- **ทำ Trunk ให้ clean + predictable** — Native VLAN 999 สำหรับทุก trunk port
|
||||
- **เผื่อ future VLAN expansion** — รองรับ VLAN เพิ่มเติมในอนาคต
|
||||
- **VLAN 999 (was 99)** — เปลี่ยนจาก VLAN 99 เป็น 999 เพื่อความปลอดภัย
|
||||
|
||||
---
|
||||
|
||||
## VLAN Definitions
|
||||
|
||||
| VLAN ID | Name | Purpose | Subnet | Gateway | DHCP Range |
|
||||
|---------|------|---------|--------|---------|-------------|
|
||||
| 10 | NAS-ADMIN | NAS Storage & Admin Desktop | 192.168.10.0/24 | 192.168.10.1 | 192.168.10.50–199 |
|
||||
| 20 | MGMT | Network Management (OC200) | 192.168.20.0/24 | 192.168.20.1 | 192.168.20.50–199 |
|
||||
| 30 | USERS | User PCs, Printers, Staff WiFi | 192.168.30.0/24 | 192.168.30.1 | 192.168.30.50–199 |
|
||||
| 40 | CCTV | CCTV Cameras, IoT Devices | 192.168.40.0/24 | 192.168.40.1 | 192.168.40.50–199 |
|
||||
| 50 | VOICE | IP Phones | 192.168.50.0/24 | 192.168.50.1 | 192.168.50.50–199 |
|
||||
| 70 | GUEST | Guest WiFi | 192.168.70.0/24 | 192.168.70.1 | 192.168.70.50–199 |
|
||||
| 999 | NATIVE | Trunk Native VLAN (No DHCP) — Hardened | — | — | — |
|
||||
| 60 | UNUSED | Reserved for future use | — | — | — |
|
||||
|
||||
---
|
||||
|
||||
## Port Profiles
|
||||
|
||||
### Profile 1 — 001-CORE-TRUNK-LACP 🔷
|
||||
|
||||
**Purpose:** LACP trunk links between Core and Access switches / Router
|
||||
|
||||
**Applied To:**
|
||||
- SG3210X-M2 Port 1–2 (to SG2428P Port 21–22)
|
||||
- SG3210X-M2 Port 9 (to ER7206)
|
||||
- SG2428P Port 21–22 (to SG3210X-M2 Port 1–2)
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Loop Protect: ENABLE
|
||||
- Root Protect: DISABLE
|
||||
- TC Guard: DISABLE
|
||||
- BPDU Guard: DISABLE
|
||||
- BPDU Filter: DISABLE
|
||||
|
||||
General:
|
||||
- Flow Control: ON
|
||||
- EEE: OFF
|
||||
- Port Isolation: OFF
|
||||
```
|
||||
|
||||
📌 **ใช้กับ:** Core ↔ Access, Core ↔ Router
|
||||
|
||||
---
|
||||
|
||||
### Profile 2 — 002-NAS-LACP 🔷
|
||||
|
||||
**Purpose:** LACP links to NAS storage devices (QNAP / ASUSTOR)
|
||||
|
||||
**Applied To:**
|
||||
- SG3210X-M2 Port 3–4 (to QNAP)
|
||||
- SG3210X-M2 Port 5–6 (to ASUSTOR)
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Loop Protect: ENABLE
|
||||
- Root Protect: DISABLE
|
||||
- BPDU Guard: DISABLE
|
||||
|
||||
General:
|
||||
- Flow Control: ON
|
||||
- EEE: OFF
|
||||
```
|
||||
|
||||
⚠️ **เหตุผล:** NAS บางรุ่นส่ง BPDU แปลก ๆ → ห้ามเปิด BPDU Guard
|
||||
|
||||
---
|
||||
|
||||
### Profile 3 — 003-UNMANAGED-SWITCH 🔷⭐ (สำคัญมาก)
|
||||
|
||||
**Purpose:** Downstream links to unmanaged switches — ป้องกัน Rogue Switch
|
||||
|
||||
**Applied To:**
|
||||
- SG2428P Port 25 (to TL-SL1226P — CCTV)
|
||||
- SG2428P Port 26 (to TL-SG1210P — IP Phone + PC)
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Root Protect: ENABLE 🔥
|
||||
- Loop Protect: ENABLE
|
||||
- BPDU Guard: DISABLE
|
||||
- TC Guard: DISABLE
|
||||
|
||||
General:
|
||||
- Flow Control: ON
|
||||
- EEE: OFF
|
||||
```
|
||||
|
||||
📌 **ป้องกัน:** เสียบ switch เถื่อน → ยึด root ไม่ได้
|
||||
|
||||
---
|
||||
|
||||
### Profile 4 — 004-AP-TRUNK 🔷
|
||||
|
||||
**Purpose:** Trunk links to wireless access points (EAP610)
|
||||
|
||||
**Applied To:**
|
||||
- SG2428P Port 1–16 (to EAP610)
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Edge Port: ENABLE
|
||||
- BPDU Guard: ENABLE 🔥 (optional แต่แนะนำ)
|
||||
- Loop Protect: DISABLE
|
||||
|
||||
General:
|
||||
- Flow Control: ON
|
||||
- EEE: OFF
|
||||
```
|
||||
|
||||
📌 **หมายเหตุ:** AP ไม่ควรส่ง BPDU → เปิด guard ได้
|
||||
|
||||
---
|
||||
|
||||
### Profile 5 — 005-VOICE-ONLY 🔷
|
||||
|
||||
**Purpose:** Direct connections to IP phones
|
||||
|
||||
**Applied To:**
|
||||
- SG2428P Port 17–18 (to IP Phone)
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Edge Port: ENABLE
|
||||
- BPDU Guard: ENABLE 🔥
|
||||
|
||||
General:
|
||||
- LLDP-MED: ENABLE
|
||||
- Flow Control: ON
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
### Profile 6 — 006-ACCESS-PC 🔷⭐
|
||||
|
||||
**Purpose:** Direct connections to PCs and printers — Hardened Access Port
|
||||
|
||||
**Applied To:**
|
||||
- SG2428P Port 23 (to Printer)
|
||||
- SG3210X-M2 Port 8 (to Admin Desktop)
|
||||
- General PC connections
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Edge Port: ENABLE
|
||||
- BPDU Guard: ENABLE 🔥🔥🔥 (สำคัญสุด)
|
||||
|
||||
General:
|
||||
- Flow Control: ON
|
||||
- EEE: OFF
|
||||
```
|
||||
|
||||
📌 **ถ้ามีคนเสียบ switch:** → Port จะ shutdown ทันที
|
||||
|
||||
---
|
||||
|
||||
### Profile 7 — 007-DEFAULT-MGMT 🔷
|
||||
|
||||
**Purpose:** Default configuration for management ports
|
||||
|
||||
**Applied To:**
|
||||
- Management ports
|
||||
- Ports requiring no special configuration
|
||||
|
||||
**Configuration:**
|
||||
|
||||
```bash
|
||||
Loopback Control: Spanning Tree
|
||||
|
||||
STP:
|
||||
- Edge Port: ENABLE
|
||||
- BPDU Guard: ENABLE
|
||||
|
||||
General:
|
||||
- Default
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## VLAN Mapping 🔶
|
||||
|
||||
### SG3210X-M2 (Core) Port Configuration
|
||||
|
||||
| Port | Destination | Profile | Native (Untagged) | Tagged | Voice |
|
||||
|------|-------------|---------|-------------------|--------|-------|
|
||||
| 1-2 | SG2428P (LACP) | 001-CORE-TRUNK-LACP | 999 | 10,20,30,40,50,70 | Off |
|
||||
| 3-4 | QNAP (LACP) | 002-NAS-LACP | 10 | 20 🔥 | Off |
|
||||
| 5-6 | ASUSTOR (LACP) | 002-NAS-LACP | 10 | 20 🔥 | Off |
|
||||
| 7 | Reserved (future expansion) | 007-DEFAULT-MGMT | 999 | None | Off |
|
||||
| 8 | Admin Desktop | 006-ACCESS-PC | 10 | None | Off |
|
||||
| 9 | ER7206 | 001-CORE-TRUNK-LACP | 999 | 10,20,30,40,50,70 | Off |
|
||||
| 10 | Reserved (future expansion) | 007-DEFAULT-MGMT | 999 | None | Off |
|
||||
|
||||
📌 **NAS (Port 3-6) ปรับใหม่:** เพิ่ม Tagged VLAN 20 สำหรับ MGMT redundancy
|
||||
|
||||
---
|
||||
|
||||
### SG2428P (Access) Port Configuration
|
||||
|
||||
| Port | Destination | Profile | Native (Untagged) | Tagged | Voice |
|
||||
|------|-------------|---------|-------------------|--------|-------|
|
||||
| 1-16 | EAP610 | 004-AP-TRUNK | 999 | 10,20,30,40,50,70 🔥 allow all | Off |
|
||||
| 17-18 | IP Phone | 005-VOICE-ONLY | 50 | None | Enable (VLAN 50) |
|
||||
| 19-20 | Reserved (future expansion) | 007-DEFAULT-MGMT | 999 | None | Off |
|
||||
| 21-22 | SG3210X-M2 (LACP) | 001-CORE-TRUNK-LACP | 999 | 10,20,30,40,50,70 | Off |
|
||||
| 23 | Printer | 006-ACCESS-PC | 30 | None | Off |
|
||||
| 24 | OC200 | 007-DEFAULT-MGMT | 20 | None | Off |
|
||||
| 25 | TL-SL1226P (CCTV) | 003-UNMANAGED-SWITCH | 40 | None | Off |
|
||||
| 26 | TL-SG1210P (IP Phone + PC) | 003-UNMANAGED-SWITCH | 30 | 50 | Enable (VLAN 50) |
|
||||
| 27-28 | Reserved (future expansion) | 007-DEFAULT-MGMT | 999 | None | Off |
|
||||
|
||||
📌 **AP Ports (1-16) ปรับใหม่:** Allow all VLANs สำหรับ future expansion
|
||||
|
||||
---
|
||||
|
||||
## Network Diagram
|
||||
|
||||
```
|
||||
┌──────────────┐
|
||||
│ ER7206 │
|
||||
│ (Trunk 999) │
|
||||
└──────┬───────┘
|
||||
│
|
||||
▼
|
||||
┌──────────────────────────┐
|
||||
│ SG3210X-M2 (Core) │
|
||||
│ [Root Bridge 4096] │
|
||||
└──────────────────────────┘
|
||||
LACP 1-2 / | | | | \ Reserved
|
||||
/ | | | | \
|
||||
▼ ▼ ▼ ▼ ▼ ▼
|
||||
SG2428P (Access) QNAP ASUSTOR Admin Reserved
|
||||
[Priority 8192] (VLAN10+20) (VLAN10+20) (VLAN10)
|
||||
(AP 1–16 Trunk)
|
||||
|
||||
Uplink SG3210X‑M2 (1–2) ↔ SG2428P (21–22)
|
||||
|
||||
WiFi Staff → VLAN 30
|
||||
WiFi Guest → VLAN 70
|
||||
CCTV → VLAN 40
|
||||
IP Phone → VLAN 50
|
||||
Printer → VLAN 30
|
||||
Admin Desktop → VLAN 10
|
||||
NAS → VLAN 10 (+20 MGMT)
|
||||
OC200 → VLAN 20
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## Configuration Procedure
|
||||
|
||||
### Step 1 — Create Port Profiles
|
||||
|
||||
1. Navigate to Omada SDN Controller → Port Profiles
|
||||
2. Create each profile listed in the Port Profiles section
|
||||
3. Configure all settings as specified
|
||||
4. **Do not configure VLANs in Port Profiles** (VLANs are configured in Edit Port)
|
||||
|
||||
### Step 2 — Configure Port VLANs
|
||||
|
||||
1. Navigate to Omada SDN Controller → Switches → Edit Port
|
||||
2. For each port, configure:
|
||||
- **Native Network (Untagged)** — The access VLAN for untagged traffic
|
||||
- **Tagged Network** — VLANs allowed on the trunk (comma-separated)
|
||||
- **Voice Network** — Voice VLAN (if applicable)
|
||||
- **Profile** — Select the appropriate Port Profile from Step 1
|
||||
3. Apply configuration per the VLAN Mapping tables
|
||||
|
||||
---
|
||||
|
||||
## Change Log
|
||||
|
||||
| Version | Date | Changes |
|
||||
|---------|------|---------|
|
||||
| 3.0 | 2026-04-24 | **FINAL VERSION** — STP-only (no Loop Detection), BPDU Guard on access ports, Root Guard on unmanaged switch ports, VLAN 99→999, NAS with MGMT redundancy (VLAN 20 tagged), AP allow-all VLANs, Security Hardening section |
|
||||
| 2.0 | 2026-04-24 | Updated port mappings (LACP 21-22), new VLAN scheme (30/40/50/70), consolidated CCTV/IoT to VLAN 40, added DHCP table, renamed PC-ONLY to ACCESS-PC |
|
||||
| 1.0 | 2026-04-23 | Initial version with basic port profiles and VLAN mapping |
|
||||
|
||||
---
|
||||
|
||||
## Quick Reference — Edit Port Values
|
||||
|
||||
### SG3210X-M2
|
||||
|
||||
| Port | Native | Tagged | Profile | Voice |
|
||||
|------|--------|--------|---------|-------|
|
||||
| 1-2 | 999 | 10,20,30,40,50,70 | 001-CORE-TRUNK-LACP | Off |
|
||||
| 3-4 | 10 | 20 | 002-NAS-LACP | Off |
|
||||
| 5-6 | 10 | 20 | 002-NAS-LACP | Off |
|
||||
| 7 | 999 | — | 007-DEFAULT-MGMT | Off |
|
||||
| 8 | 10 | — | 006-ACCESS-PC | Off |
|
||||
| 9 | 999 | 10,20,30,40,50,70 | 001-CORE-TRUNK-LACP | Off |
|
||||
| 10 | 999 | — | 007-DEFAULT-MGMT | Off |
|
||||
|
||||
### SG2428P
|
||||
|
||||
| Port | Native | Tagged | Profile | Voice |
|
||||
|------|--------|--------|---------|-------|
|
||||
| 1-16 | 999 | 10,20,30,40,50,70 | 004-AP-TRUNK | Off |
|
||||
| 17-18 | 50 | — | 005-VOICE-ONLY | 50 |
|
||||
| 19-20 | 999 | — | 007-DEFAULT-MGMT | Off |
|
||||
| 21-22 | 999 | 10,20,30,40,50,70 | 001-CORE-TRUNK-LACP | Off |
|
||||
| 23 | 30 | — | 006-ACCESS-PC | Off |
|
||||
| 24 | 20 | — | 007-DEFAULT-MGMT | Off |
|
||||
| 25 | 40 | — | 003-UNMANAGED-SWITCH | Off |
|
||||
| 26 | 30 | 50 | 003-UNMANAGED-SWITCH | 50 |
|
||||
| 27-28 | 999 | — | 007-DEFAULT-MGMT | Off |
|
||||
|
||||
---
|
||||
|
||||
## Pre-Deployment Checklist
|
||||
|
||||
ก่อน Apply ค่า Configuration:
|
||||
- [ ] สร้าง VLANs 10, 20, 30, 40, 50, 70, 999 ใน Omada Controller (VLAN 999 = Hardened Native)
|
||||
- [ ] สร้าง Port Profiles 001–007 ครบถ้วน (STP Mode — ไม่ใช้ Loop Detection)
|
||||
- [ ] ตรวจสอบ LACP Group Configuration (Port 1-2 ↔ Port 21-22)
|
||||
- [ ] ตั้งค่า DHCP Server ตามตาราง VLAN Definitions
|
||||
- [ ] ตรวจสอบว่า OC200 อยู่บน VLAN 20 และมี IP 192.168.20.x
|
||||
- [ ] ตรวจสอบ Voice VLAN Enable บน Port 17-18 และ 26
|
||||
- [ ] กำหนด STP Priority: Core=4096, Access=8192
|
||||
- [ ] สำรอง Configuration ปัจจุบันก่อน Apply
|
||||
|
||||
---
|
||||
|
||||
# Testing Guide — VLAN + LACP + STP
|
||||
|
||||
การทดสอบทีละ Layer โดยไม่ต้องใช้เครื่องมือพิเศษ — ใช้แค่ PC + ping + OC200 UI
|
||||
|
||||
---
|
||||
|
||||
## PART 1 — Testing VLAN (Step-by-Step)
|
||||
|
||||
### Goal
|
||||
- ตรวจสอบว่าแต่ละพอร์ตอยู่ VLAN ถูกต้อง
|
||||
- ตรวจสอบว่า Tagged/Untagged ทำงาน
|
||||
- ตรวจสอบว่า DHCP แจก IP ถูก subnet
|
||||
- ตรวจสอบว่า WiFi → VLAN ถูกต้อง
|
||||
|
||||
---
|
||||
|
||||
### STEP 1 — Test VLAN 10 (NAS-ADMIN)
|
||||
|
||||
**Test Equipment:**
|
||||
- Admin Desktop (Port 8 SG3210X-M2)
|
||||
- QNAP / ASUSTOR
|
||||
|
||||
**Procedure:**
|
||||
1. Connect Admin Desktop → Port 8
|
||||
2. Open Command Prompt
|
||||
3. Type:
|
||||
```
|
||||
ipconfig
|
||||
```
|
||||
4. Expected IP range:
|
||||
```
|
||||
192.168.10.x
|
||||
```
|
||||
|
||||
**Ping Tests:**
|
||||
```
|
||||
ping 192.168.10.1 ← Gateway
|
||||
ping <QNAP-IP>
|
||||
ping <ASUSTOR-IP>
|
||||
```
|
||||
|
||||
**Expected Result:**
|
||||
- All pings successful
|
||||
- Should NOT ping to VLAN 30/40/50/70 (if ACL configured)
|
||||
|
||||
---
|
||||
|
||||
### STEP 2 — Test VLAN 30 (USERS)
|
||||
|
||||
**Test Equipment:**
|
||||
- General PC
|
||||
- Printer
|
||||
- Staff WiFi (SSID: Staff)
|
||||
|
||||
**Procedure:**
|
||||
1. Connect PC → Port 23 or Port 26 (via TL-SG1210P)
|
||||
2. Type:
|
||||
```
|
||||
ipconfig
|
||||
```
|
||||
3. Expected IP:
|
||||
```
|
||||
192.168.30.x
|
||||
```
|
||||
|
||||
**Ping Tests:**
|
||||
```
|
||||
ping 192.168.30.1
|
||||
ping <Printer-IP>
|
||||
```
|
||||
|
||||
**WiFi Staff Test:**
|
||||
1. Connect to SSID Staff
|
||||
2. Type:
|
||||
```
|
||||
ipconfig
|
||||
```
|
||||
3. Expected IP: 192.168.30.x
|
||||
|
||||
---
|
||||
|
||||
### STEP 3 — Test VLAN 40 (CCTV/IoT)
|
||||
|
||||
**Test Equipment:**
|
||||
- CCTV Camera (via TL-SL1226P Port 25)
|
||||
|
||||
**Procedure:**
|
||||
1. Open OC200 → Clients
|
||||
2. Camera must show as VLAN 40
|
||||
3. Test ping from Admin Desktop:
|
||||
```
|
||||
ping <CCTV-IP>
|
||||
```
|
||||
|
||||
**Expected Result:**
|
||||
- Ping successful
|
||||
- DHCP must assign IP 192.168.40.x
|
||||
|
||||
---
|
||||
|
||||
### STEP 4 — Test VLAN 50 (VOICE)
|
||||
|
||||
**Test Equipment:**
|
||||
- IP Phone (Port 17–18 SG2428P)
|
||||
|
||||
**Procedure:**
|
||||
1. IP Phone boots up
|
||||
2. Expected IP:
|
||||
```
|
||||
192.168.50.x
|
||||
```
|
||||
3. In OC200 → Clients, must see Voice VLAN 50
|
||||
|
||||
**LLDP-MED Test:**
|
||||
In OC200 → Switch → Port 17–18, must see:
|
||||
```
|
||||
LLDP-MED: Active
|
||||
Voice VLAN: 50
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
### STEP 5 — Test VLAN 70 (Guest WiFi)
|
||||
|
||||
**Procedure:**
|
||||
1. Connect to SSID Guest
|
||||
2. Type:
|
||||
```
|
||||
ipconfig
|
||||
```
|
||||
3. Expected IP:
|
||||
```
|
||||
192.168.70.x
|
||||
```
|
||||
|
||||
**Isolation Test:**
|
||||
```
|
||||
ping 192.168.30.1 ← Must NOT pass
|
||||
ping 192.168.10.1 ← Must NOT pass
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
## PART 2 — Testing LACP (Step-by-Step)
|
||||
|
||||
### Goal
|
||||
- ตรวจสอบว่า LACP ระหว่าง SG3210X-M2 ↔ SG2428P ทำงาน
|
||||
- ตรวจสอบว่า QNAP/ASUSTOR LACP ทำงาน
|
||||
- ตรวจสอบว่าไม่มี Mis-config
|
||||
|
||||
---
|
||||
|
||||
### STEP 1 — Check LACP Status in OC200
|
||||
|
||||
**Path:** Insight → Switch → LAG Status
|
||||
|
||||
Expected status:
|
||||
|
||||
**SG3210X-M2:**
|
||||
- LAG1 (Port 1–2) → **Up**
|
||||
- LAG2 (Port 3–4) → **Up**
|
||||
- LAG3 (Port 5–6) → **Up**
|
||||
|
||||
**SG2428P:**
|
||||
- LAG1 (Port 21–22) → **Up**
|
||||
|
||||
---
|
||||
|
||||
### STEP 2 — Test Load Balancing
|
||||
|
||||
**Procedure:**
|
||||
1. Open QNAP → File Station
|
||||
2. Copy large file (10–20GB) to Admin Desktop
|
||||
3. Open Task Manager → Performance → Ethernet
|
||||
4. Must see traffic on both links (Port 3–4 or 5–6)
|
||||
|
||||
**Uplink Test:**
|
||||
1. Run Speedtest between PC VLAN 30 → NAS VLAN 10
|
||||
2. Must achieve > 1Gbps (if 2Gbps LACP)
|
||||
|
||||
---
|
||||
|
||||
### STEP 3 — Test Failover
|
||||
|
||||
**Procedure:**
|
||||
1. Disconnect cable from **Port 1** of SG3210X-M2
|
||||
2. LACP must remain **Up** (using Port 2)
|
||||
3. Disconnect Port 2 → LACP must go Down
|
||||
|
||||
Repeat test with QNAP/ASUSTOR
|
||||
|
||||
---
|
||||
|
||||
## PART 3 — Testing STP (Step-by-Step)
|
||||
|
||||
### Goal
|
||||
- ตรวจสอบว่าไม่มี Loop
|
||||
- ตรวจสอบว่า Root Bridge ถูกต้อง
|
||||
- ตรวจสอบว่า STP Security ทำงาน
|
||||
|
||||
---
|
||||
|
||||
### STEP 1 — Check Root Bridge
|
||||
|
||||
**Path:** Devices → SG3210X-M2 → Ports → STP
|
||||
|
||||
Expected:
|
||||
```
|
||||
SG3210X-M2 = Root Bridge
|
||||
```
|
||||
|
||||
If not, adjust Priority:
|
||||
```
|
||||
SG3210X-M2 Priority = 4096
|
||||
SG2428P Priority = 8192
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
### STEP 2 — Test Loop Detection
|
||||
|
||||
**Safe Test Method:**
|
||||
1. Go to TL-SG1210P (Port 26 SG2428P)
|
||||
2. Create loop with LAN cable (Port 1 ↔ Port 2)
|
||||
3. Check OC200 → Alerts
|
||||
|
||||
Expected alert:
|
||||
```
|
||||
Loop Detected on Port 26
|
||||
Port Shutdown (BPDU Protect)
|
||||
```
|
||||
|
||||
Port must auto-shutdown
|
||||
|
||||
---
|
||||
|
||||
### STEP 3 — Test STP Blocking
|
||||
|
||||
**Procedure:**
|
||||
1. Connect cable from SG2428P Port 19 → SG2428P Port 20
|
||||
2. Check OC200 → Switch → Ports
|
||||
|
||||
Expected:
|
||||
```
|
||||
STP State: Blocking
|
||||
```
|
||||
|
||||
---
|
||||
|
||||
### STEP 4 — Test Topology Change (TC Guard)
|
||||
|
||||
**Procedure:**
|
||||
1. Power cycle AP (Port 1–16)
|
||||
2. Check OC200 → Logs
|
||||
|
||||
Expected: **NO** message:
|
||||
```
|
||||
Topology Change Detected
|
||||
```
|
||||
|
||||
Because TC Guard is enabled
|
||||
|
||||
---
|
||||
|
||||
## PART 4 — Testing Checklist (SOP)
|
||||
|
||||
### VLAN Tests
|
||||
- [ ] VLAN 10 gets IP 192.168.10.x
|
||||
- [ ] VLAN 30 gets IP 192.168.30.x
|
||||
- [ ] VLAN 40 gets IP 192.168.40.x
|
||||
- [ ] VLAN 50 gets IP 192.168.50.x
|
||||
- [ ] VLAN 70 gets IP 192.168.70.x
|
||||
|
||||
### WiFi Tests
|
||||
- [ ] Staff WiFi → VLAN 30
|
||||
- [ ] Guest WiFi → VLAN 70
|
||||
|
||||
### Device Tests
|
||||
- [ ] CCTV → VLAN 40
|
||||
- [ ] IP Phone → VLAN 50
|
||||
- [ ] Printer → VLAN 30
|
||||
- [ ] Admin Desktop → VLAN 10
|
||||
- [ ] NAS → VLAN 10
|
||||
- [ ] OC200 → VLAN 20
|
||||
|
||||
### LACP Tests
|
||||
- [ ] LACP SG3210X-M2 ↔ SG2428P = Up
|
||||
- [ ] LACP QNAP = Up
|
||||
- [ ] LACP ASUSTOR = Up
|
||||
- [ ] Load balancing works (2Gbps)
|
||||
- [ ] Failover works (single link failure)
|
||||
|
||||
### STP Tests
|
||||
- [ ] Root Bridge = SG3210X-M2 (Priority 4096)
|
||||
- [ ] BPDU Guard shutdown test (เสียบ switch ที่ port PC → port ต้อง shutdown)
|
||||
- [ ] Root Guard works (003-UNMANAGED-SWITCH)
|
||||
- [ ] STP Blocking works
|
||||
- [ ] TC Guard works (no topology change on AP reboot)
|
||||
|
||||
---
|
||||
|
||||
# 🔐 Security Hardening (ต้องทำเพิ่ม)
|
||||
|
||||
Required security configurations for Enterprise-grade network protection.
|
||||
|
||||
---
|
||||
|
||||
## DHCP Snooping 🔥
|
||||
|
||||
```bash
|
||||
Global: ENABLE
|
||||
|
||||
Trusted Ports:
|
||||
- Uplink ไป Router (ER7206)
|
||||
- Core Trunk (Port 1-2, 9)
|
||||
```
|
||||
|
||||
**Path:** Settings → Wired Networks → Switch → DHCP Snooping
|
||||
|
||||
1. Enable **DHCP Snooping** globally
|
||||
2. Mark **Trusted Ports**:
|
||||
- SG3210X-M2 Port 9 (to ER7206)
|
||||
- SG3210X-M2 Port 1-2 (Core Trunk)
|
||||
- SG2428P Port 21-22 (Uplink to Core)
|
||||
3. **Untrusted:** ทุก access port (จะถูก block ถ้าส่ง DHCP Offer)
|
||||
|
||||
---
|
||||
|
||||
## Storm Control (AP Ports) 🔥
|
||||
|
||||
```bash
|
||||
Broadcast: 1%
|
||||
Multicast: 2%
|
||||
Unknown: 2%
|
||||
```
|
||||
|
||||
**Path:** Settings → Wired Networks → Switch → Port Profile → 004-AP-TRUNK
|
||||
|
||||
1. Navigate to **Bandwidth Control / Storm Control**
|
||||
2. Configure:
|
||||
- Broadcast: 1% (หรือ 1000 pps)
|
||||
- Multicast: 2% (หรือ 2000 pps)
|
||||
- Unknown Unicast: 2% (หรือ 2000 pps)
|
||||
3. Save
|
||||
|
||||
📌 **หมายเหตุ:** ใช้ percentage หรือ pps ตามความเหมาะสมกับ traffic
|
||||
|
||||
---
|
||||
|
||||
## STP Priority (Root Bridge Election) 🔥
|
||||
|
||||
```bash
|
||||
SG3210X-M2 (Core): 4096
|
||||
SG2428P (Access): 8192
|
||||
```
|
||||
|
||||
**Path:** Devices → Switch → Config → STP → Priority
|
||||
|
||||
1. **SG3210X-M2:** Set Priority = **4096** (Root Bridge)
|
||||
2. **SG2428P:** Set Priority = **8192** (Backup Root)
|
||||
3. Save and verify:
|
||||
```
|
||||
OC200 → Topology → Root Bridge = SG3210X-M2
|
||||
```
|
||||
|
||||
📌 **สำคัญ:** Core ต้องเป็น Root Bridge เสมอ
|
||||
|
||||
---
|
||||
|
||||
## Jumbo Frame 🔥
|
||||
|
||||
```bash
|
||||
MTU: 9000
|
||||
(ต้องตั้งทุก device ให้เท่ากัน)
|
||||
```
|
||||
|
||||
### SG3210X-M2
|
||||
**Path:** Devices → SG3210X-M2 → Config → Switch Settings
|
||||
```
|
||||
Jumbo Frame: Enable
|
||||
MTU: 9000
|
||||
```
|
||||
|
||||
### QNAP
|
||||
**Path:** Control Panel → Network & Virtual Switch → Interfaces
|
||||
```
|
||||
MTU: 9000
|
||||
```
|
||||
|
||||
### ASUSTOR
|
||||
**Path:** Settings → Network → Interface → Advanced
|
||||
```
|
||||
Jumbo Frame: 9000
|
||||
```
|
||||
|
||||
⚠️ **คำเตือน:** ถ้าตั้งไม่เท่ากันทุก device → จะมีปัญหา fragmentation หรือ packet drop
|
||||
|
||||
---
|
||||
|
||||
## 💥 Final Validation Checklist
|
||||
|
||||
### Connectivity Tests
|
||||
- [ ] LACP = UP ทุกเส้น (Core↔Access, NAS)
|
||||
- [ ] Root Bridge = Core Switch (SG3210X-M2 Priority 4096)
|
||||
- [ ] เสียบ switch ที่ port PC → port ต้อง shutdown (BPDU Guard)
|
||||
- [ ] WiFi ได้ VLAN ถูกต้อง (Staff=30, Guest=70)
|
||||
- [ ] NAS เข้าถึงได้ทั้ง VLAN 10 และ 20
|
||||
- [ ] Guest VLAN เข้า LAN ไม่ได้ (isolation)
|
||||
|
||||
### Security Tests
|
||||
- [ ] DHCP Snooping blocks rogue DHCP
|
||||
- [ ] Storm Control limits broadcast
|
||||
- [ ] BPDU Guard shuts down unauthorized switches
|
||||
- [ ] Root Guard prevents rogue root bridge
|
||||
|
||||
### Performance Tests
|
||||
- [ ] Jumbo Frame works (MTU 9000 end-to-end)
|
||||
- [ ] LACP load balancing (2Gbps aggregate)
|
||||
- [ ] Failover works (single link failure)
|
||||
|
||||
---
|
||||
|
||||
## Related Documents
|
||||
|
||||
- Network Architecture Design — `specs/02-architecture/02-03-network-design.md`
|
||||
- VLAN Scheme — See [VLAN Definitions](#vlan-definitions) section
|
||||
- IP Addressing Scheme — See DHCP table in [VLAN Definitions](#vlan-definitions) section
|
||||
- Security Guidelines — `specs/06-Decision-Records/ADR-016-security-authentication.md`
|
||||
- Release Policy — `specs/04-Infrastructure-OPS/04-08-release-management-policy.md` (สำหรับ network changes)
|
||||
|
||||
---
|
||||
|
||||
## Document Metadata
|
||||
|
||||
| Property | Value |
|
||||
|----------|-------|
|
||||
| **Type** | Infrastructure Specification |
|
||||
| **Language** | Thai (explanations), English (technical terms) |
|
||||
| **Standards** | AGENTS.md v1.8.9 |
|
||||
| **Review Cycle** | Per release or on equipment change |
|
||||
| **Approval Required** | Yes — Infrastructure Lead + Security Review |
|
||||
|
||||
|
||||
|
||||
Reference in New Issue